Home / Products

DFW2-12/630 Cable Branch Box

DFW2-12/630 is an outdoor cable branch box for connection and branching in medium-voltage distribution networks. The documented equipment rating is 12 kV and 630 A. Conventional cable-connection arrangements and configurations incorporating an SF6 load switch serve different circuit requirements. Select the number of branches, cable interfaces, switching arrangement and protection functions from the project single-line diagram.

Send the model, required ratings, quantity, installation conditions and destination. Include a single-line diagram or specification when available.

DFW2-12/630 Cable Branch Box is equipment for connecting and branching medium-voltage cables. Distinguish the cable-connection arrangement from switch-equipped options when reviewing the component ratings and protection requirements.

DFW2-12/630 Cable Branch Box Specifications

Series Electrical Data

Parameter Specification / configuration
Rated voltage 12 kV
Rated current 630 A
Installation Outdoor cable distribution
Cable connection Insulated, screened cable interfaces; arrangement selected for the circuit

Configuration with SF6 Load Switch

Parameter Specification / configuration
Rated short-time withstand current 20 kA for 3 s
Rated peak withstand current 50 kA
Power-frequency withstand voltage 42 kV for 1 min
Secondary-circuit power-frequency withstand voltage 2 kV for 1 min
Cable-charging breaking current 10 A
Closed-loop breaking current 630 A
Mechanical operating life 2000 operations
Enclosure protection IP43 for the documented configuration

Service Conditions

Parameter Specification / configuration
Altitude Up to 2000 m
Daily mean relative humidity Up to 95%
Monthly mean relative humidity Up to 90%
Site conditions No persistent severe vibration or corrosive exposure

Ratings and options apply to the selected configuration. The agreed drawings and equipment schedule define the supplied assembly.

Cable connection and switching arrangements

A conventional cable branch box connects incoming and outgoing cables through insulated interfaces. A switch-equipped arrangement adds circuit switching and may include fuse or circuit-breaker protection, depending on the selected scheme. The load-switch ratings above apply to the documented switched arrangement and should not be read as a rating for every cable connector or optional protective device.

Planning the outdoor installation

Define the available footprint, cable entry direction, cable size and termination system before selecting the enclosure. Access for operation, earthing, maintenance and safe isolation should be coordinated with the wider network. Surge arresters and fault indication can be considered where required by the electrical scheme.

Information for Selection

  • System voltage and single-line diagram
  • Incoming/outgoing branch count and cable sizes
  • Conventional or switched arrangement and protection requirements
  • Site exposure, cable entry and access requirements

Explore the application solutions for your industry and include the project specification with your enquiry.

Related voltage and acceptance questions

Distinguish the network’s nominal voltage from the selected equipment rating using the 10 kV versus 12 kV guide. State whether the enquiry is for cable branching only or a switch-equipped arrangement so that the relevant component and protection ratings can be reviewed.

Agree the factory inspection and document scope for the actual arrangement. The medium-voltage catalogue helps compare other circuit functions, while the enquiry checklist lists the project data to supply.