Home / Products

XL-21 Indoor Power Distribution Cabinet

XL-21 is a fixed enclosed indoor low-voltage distribution cabinet for power, lighting and equipment circuits. The supplied product data describes 380 V, 50 Hz systems with operating current up to 600 A. The incoming device, outgoing circuit arrangement, protection and cable connections are selected for the application. Indoor installation and the required operating access are reviewed when defining the cabinet.

Send the model, required ratings, quantity, installation conditions and destination. Include a single-line diagram or specification when available.

XL-21 Distribution Cabinet is a fixed enclosed indoor low-voltage family for power, lighting and equipment circuits. Identify the incoming supply, outgoing circuit schedule, protective devices and cable interfaces before selecting an arrangement.

XL-21 Distribution Cabinet Specifications

Main Product Data

Parameter Specification / configuration
Rated operating voltage 380 V AC
Rated frequency 50 Hz
Operating current Up to 600 A
Construction Fixed enclosed distribution cabinet
Degree of protection IP20
Installation Indoor

Service Conditions

Parameter Specification / configuration
Maximum ambient temperature +40 °C
24-hour mean temperature Up to +35 °C
Altitude Up to 2000 m
Relative humidity Up to 50% at +40 °C or 90% at +20 °C
Site conditions No persistent severe vibration, impact or corrosive exposure

Ratings and options apply to the selected configuration. The agreed drawings and equipment schedule define the supplied assembly.

Power and lighting distribution

The cabinet provides an enclosure for the selected switching and protective devices. The number of outgoing circuits, phase arrangement, protective-device ratings and metering functions are defined from the load schedule. Power and lighting circuits can have different requirements and should be identified separately.

Specify the enclosure and connections

State the available installation space, cable entry direction, operating access and the environment inside the electrical room. The final dimensions and internal arrangement are determined from the selected devices, conductor sizes and installation requirements. Additional enclosure protection should be agreed as a specific configuration.

Information for Selection

  • Incoming supply and total operating current
  • Outgoing circuit count, loads and protection requirements
  • Cabinet dimensions, cable entry and operating access
  • Metering, auxiliary circuits and installation conditions

Explore the application solutions for your industry and include the project specification with your enquiry.